240W Single Output with PFC Function Features : Universal AC input / Full range SP-240 series Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC Fan Built-in fan ON / OFF control LED indicator for power on Fixed switching frequency at 90KHz 3 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) SP-240-5 5V 45A 0 ~ 45A 225W 4 ~ 6V 2.0% 0.5% 1.0% 20ms/230VAC SP-240-7.5 7.5V 32A 0 ~ 32A 240W 150mVp-p 6 ~ 9V 2.0% 0.5% 1.0% SP-240-12 12V 20A 0 ~ 20A 240W 150mVp-p 10 ~ 14V 1.0% 0.3% 0.5% SP-240-15 15V 16A 0 ~ 16A 240W 150mVp-p 12 ~ 18V 1.0% 0.3% 0.5% SP-240-24 24V 10A 0 ~ 10A 240W 150mVp-p 20 ~ 28V 1.0% 0.2% 0.5% SP-240-30 30V 8A 0 ~ 8A 240W 150mVp-p 27 ~ 33V 1.0% 0.2% 0.5% SP-240-48 48V 5A 0 ~ 5A 240W 150mVp-p 41 ~ 56V 1.0% 0.2% 0.5% RIPPLE & NOISE (max.) Note.2 150mVp-p 800ms, 50ms/230VAC 1500ms, 50ms/115VAC at full load 20ms/115VAC at full load 124 ~ 370VDC PF>0.98/115VAC at full load 83% 1.8A/230VAC 40A/230VAC 86% 86% 87% 88% 89% VOLTAGE RANGE Note.5 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE FUNCTION FAN CONTROL WORKING TEMP. PF>0.95/230VAC 79% 3.6A/115VAC 25A/115VAC <2mA / 240VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 9.4 ~ 10.9V 14.7 ~ 17.5V 19 ~ 22.5V 29.5 ~ 35V 6.3 ~ 7.5V Protection type : Shut down o/p voltage, re-power on to recover 90 5 (5V,7.5V), 85 5 34.7 ~ 41V 57.6 ~ 67.2V (12V,15V,24V,30V,48V) (TSW1 : detect on heatsink of power transistor) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down RTH2 40 FAN ON, 35 FAN OFF(Typ.) -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY MTBF I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 284K hrs min. MIL-HDBK-217F (25 ) 190*93*50mm (L*W*H) 0.8Kg; 18pcs/15.4Kg/1.04CUFT OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:SP-240-SPEC 2009-09-02 240W Single Output with PFC Function Mechanical Specification US P --2 4 0 SP 320 25 Case No.987A s e r ii e s ser es Unit:mm 4-M4 L=6 20.25 159.5 139.5 133 49.5 20 150 7 6 4 43.5 41.5 60.5 3 2 1 8 84.5 9.5 190 20.25 150 44 93 Air flow direction 5 4-SO M3 L=4 12.5 12.5 25 Terminal Pin No. Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4,5 6,7 Assignment DC OUTPUT -V DC OUTPUT +V 50 14max. Block Diagram FAN ON/OFF CONTROL EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. FAN 25 4-M4 L=6 fosc : 90KHz I/P +V -V FG O.L.P. O.T.P. PWM & PFC CONTROL Derating Curve Static Characteristics Ta=25 100 100 90 300 250 200 150 100 50 25 80 80 70 60 LOAD (%) LOAD (%) 0 10 20 30 40 50 60 70 (HORIZONTAL) 50 40 60 50 40 20 -20 88 90 95 100 115 135 155 175 195 230 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:SP-240-SPEC 2009-09-02 |
Price & Availability of SP-240-12 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |